Phone: (+39) 0813995453


Feasibility of differentiating gait in Parkinson's disease and spinocerebellar degeneration using a pose estimation algorithm in two-dimensional video

HumanInsight

Feasibility of differentiating gait in Parkinson's disease and spinocerebellar degeneration using a pose estimation algorithm in two-dimensional video

J Neurol Sci. 2024 Jul 30;464:123158. doi: 10.1016/j.jns.2024.123158. Online ahead of print.

ABSTRACT

BACKGROUND: Although pose estimation algorithms have been used to analyze videos of patients with Parkinson's disease (PD) to assess symptoms, their feasibility for differentiating PD from other neurological disorders that cause gait disturbances has not been evaluated yet. We aimed to determine whether it was possible to differentiate between PD and spinocerebellar degeneration (SCD) by analyzing video recordings of patient gait using a pose estimation algorithm.

METHODS: We videotaped 82 patients with PD and 61 patients with SCD performing the timed up-and-go test. A pose estimation algorithm was used to extract the coordinates of 25 key points of the participants from these videos. A transformer-based deep neural network (DNN) model was trained to predict PD or SCD using the extracted coordinate data. We employed a leave-one-participant-out cross-validation method to evaluate the predictive performance of the trained model using accuracy, sensitivity, and specificity. As there were significant differences in age, weight, and body mass index between the PD and SCD groups, propensity score matching was used to perform the same experiment in a population that did not differ in these clinical characteristics.

RESULTS: The accuracy, sensitivity, and specificity of the trained model were 0.86, 0.94, and 0.75 for all participants and 0.83, 0.88, and 0.78 for the participants extracted by propensity score matching.

CONCLUSION: The differentiation of PD and SCD using key point coordinates extracted from gait videos and the DNN model was feasible and could be used as a collaborative tool in clinical practice and telemedicine.

PMID:39096835 | DOI:10.1016/j.jns.2024.123158

Powered by WPeMatico

P.IVA 08738511214
Privacy Policy
Cookie Policy

Sede Legale
Viale Campi Flegrei 55
80124 - Napoli

Sede Operativa
Via G.Porzio 4
Centro Direzionale G1
80143 - Napoli

ISO9001
AI 4394
© Copyright 2022 - Humaninsight Srls - All Rights Reserved
Privacy Policy | Cookie Policy
envelopephone-handsetmap-marker linkedin facebook pinterest youtube rss twitter instagram facebook-blank rss-blank linkedin-blank pinterest youtube twitter instagram