Phone: (+39) 0813995453


Absolute cardiovascular risk assessment using 'real world' clinic blood pressures compared to standardized unobserved and ambulatory methods: an observational study

HumanInsight

Absolute cardiovascular risk assessment using 'real world' clinic blood pressures compared to standardized unobserved and ambulatory methods: an observational study

Hypertens Res. 2024 Aug 16. doi: 10.1038/s41440-024-01841-1. Online ahead of print.

ABSTRACT

Clinic blood pressure (BP) is recommended for absolute cardiovascular disease (CVD) risk assessment. However, in 'real-world' settings, clinic BP measurement is unstandardised and less reliable compared to more rigorous methods but the impact for absolute CVD risk assessment is unknown. This study aimed to determine the difference in absolute CVD risk assessment using real-world clinic BP compared to standardised BP methods. Participants were patients (n = 226, 59 ± 15 years; 58% female) with hypertension referred to a BP clinic for assessment. 'Real-world' clinic BP was provided by the referring doctor. All participants had unobserved automated office BP (AOBP) and 24-h ambulatory BP monitoring (ABPM) measured at the clinic. Absolute CVD risk was calculated (Framingham) using systolic BP from the referring doctor (clinic BP), AOBP and ABPM, with agreement assessed by Kappa statistic. Clinic systolic BP was 18 mmHg than AOBP and daytime ABPM and 22 mmHg higher than 24-h ABPM (p < 0.001). Subsequently, absolute CVD risk scores using clinic BP were higher compared to AOBP, daytime ABPM and 24-h ABPM (10.4 ± 8.1%, 7.8 ± 6.4%, 7.8 ± 6.3%, and 7.3 ± 6.1%, respectively, P < 0.001). As a result, more participants were classified as high CVD risk using clinic BP (n = 89, 40%) compared with AOBP (n = 44, 20%) daytime ABPM (n = 38, 17%) and 24-h ABPM (n = 38, 17%) (p < 0.001) with weak agreement in risk classification (κ = 0.57[0.45-0.69], κ = 0.52[0.41-0.64] and κ = 0.55[0.43-0.66], respectively). Real-world clinic BP was higher and classified twice as many participants at high CVD risk compared to AOBP or ABPM. Given the challenges to high-quality BP measurement in clinic, more rigorous BP measurement methods are needed for absolute CVD risk assessment.

PMID:39152256 | DOI:10.1038/s41440-024-01841-1

Powered by WPeMatico

P.IVA 08738511214
Privacy Policy
Cookie Policy

Sede Legale
Viale Campi Flegrei 55
80124 - Napoli

Sede Operativa
Via G.Porzio 4
Centro Direzionale G1
80143 - Napoli

ISO9001
AI 4394
© Copyright 2022 - Humaninsight Srls - All Rights Reserved
Privacy Policy | Cookie Policy
envelopephone-handsetmap-marker linkedin facebook pinterest youtube rss twitter instagram facebook-blank rss-blank linkedin-blank pinterest youtube twitter instagram