Evaluation of the Accuracy of ECG Captured by CardioChip through Comparison of Lead I Recording to a Standard 12-Lead ECG Recording Device.

Evaluation of the Accuracy of ECG Captured by CardioChip through Comparison of Lead I Recording to a Standard 12-Lead ECG Recording Device.

Evaluation of the Accuracy of ECG Captured by CardioChip through Comparison of Lead I Recording to a Standard 12-Lead ECG Recording Device.

Acta Cardiol Sin. 2018 Mar;34(2):144-151

Authors: Lo CI, Chang SS, Tsai JP, Kuo JY, Chen YJ, Huang MY, Lee CH, Sung KT, Hung CL, Jia-Yin Hou C, Lai E, Yeh HI, Chang WL, Chang WH

Abstract
Background: Remote cardiac rhythm monitoring and recording, using hand-carried electrocardiogram (ECG) device had been widely used in telemedicine. The feasibility and accuracy analysis on the data recorded by a new miniature ECG system-on-chip (SoC) system has not been explored before.
Methods: This study evaluated the accuracy of the ECG recordings captured by CardioChip - a single-channeled, low-powered, miniature ECG SoC designed for mobile applications; comparing against Philips Pagewriter Trim III - a Food and Drug Administration certified, widely-used standard 12-lead ECG recording device, within Mackay Memorial Hospital in Taiwan.
Results: Total of 111 participants, age ranging from 39 to 87years old [mean age: 61.2 ± 13.4, 57 male (51.3%)] were enrolled. Two experienced cardiologists rated and scored the ECG morphology to be the same between the two devices, while CardioChip ECG was more sensitive to baseline noise. R-peak amplitudes measured both devices using single lead information (CardioChip ECG vs. Lead 1 in standard 12-lead ECG) showed statistical consistency. Offline analysis of signal correlation coefficients and coherence showed good correlation with both over 0.94 in average (0.94 ± 0.04 and 0.95 ± 0.04, respectively), high agreement between raters (94% agreement) for detecting abnormal cardiac rhythm with excellent R-peak amplitude (r = 0.98, p < 0.001) and PR interval (r = 0.91, p < 0.001) correlations, indicating excellent correlation between ECG recordings derived from two different modalities.
Conclusions: The results suggested that CardioChip ECG is comparable to medical industry standard ECG. The future implementation of wearable ECG device embedded with miniature ECG system-on-chip (SoC) system is ready for clinical use, which will potentially enhance efficacy on identifying subjects with suspected cardiac arrhythmias.

PMID: 29643700 [PubMed]

Powered by WPeMatico

P.IVA 08738511214
Privacy Policy
Cookie Policy

Sede Legale
Viale Campi Flegrei 55
80124 - Napoli

Sede Operativa
Via G.Porzio 4
Centro Direzionale G1
80143 - Napoli

ISO9001
AI 4394
© Copyright 2022 - Humaninsight Srls - All Rights Reserved
Privacy Policy | Cookie Policy
envelopephone-handsetmap-marker linkedin facebook pinterest youtube rss twitter instagram facebook-blank rss-blank linkedin-blank pinterest youtube twitter instagram