Phone: (+39) 0813995453


In vivo comparison of key quantitative parameters measured with 3D peripheral angiography, 2D peripheral quantitative angiography and intravascular ultrasound.

In vivo comparison of key quantitative parameters measured with 3D peripheral angiography, 2D peripheral quantitative angiography and intravascular ultrasound.

Related Articles

In vivo comparison of key quantitative parameters measured with 3D peripheral angiography, 2D peripheral quantitative angiography and intravascular ultrasound.

Int J Cardiovasc Imaging. 2019 Feb 22;:

Authors: Zasada W, Slezak M, Pociask E, Malinowski KP, Proniewska K, Buszman P, Milewski K, Granada JF, Kaluza GL

Abstract
The aim of this study was to compare the measures of luminal stenosis between the two-dimensional (2D) and three-dimensional (3D) Quantitative Vessel Analysis (QVA) generated by CAAS QVA software and intravascular ultrasound (IVUS). Invasive contrast angiography is considered gold standard for diagnostic imaging and intervention in both coronary and peripheral arterial disease. However, it is based on 2D images depicting complicated 3D arterial anatomy. To overcome these limitations, 3D QVA has been developed to bridge the gap between 2D QVA and endovascular imaging. Thirty porcine femoral angiograms (common, profunda and superficial) with matching intravascular ultrasound (IVUS) pullbacks featuring variable degree of stenosis were analysed by 2D QVA, 3D QVA and quantitative IVUS. All 3 modalities provided similar data regarding the length of the investigated segment. Median lumen diameter was nearly identical in IVUS (4.69 mm) and in 3D QVA (4.76 mm) but quite a bit lower in 2D QVA (4.47 mm, Kruskal-Wallis test p = 0.1648). Lumen area measured in 2D QVA was lower than in IVUS and in 3D QVA. Lumen areas rendered by IVUS and 3D QVA were similar. Bland-Altman plots showed that the lowest differences were observed between IVUS and 3D QVA. IVUS and 3D QVA results were consistently higher than 2D QVA. 3D QVA is a useful surrogate of IVUS for precise luminal morphology measurements of peripheral arteries, rendering results that are much closer to IVUS than 2D QVA can provide.

PMID: 30796556 [PubMed - as supplied by publisher]

Powered by WPeMatico

P.IVA 08738511214
Privacy Policy
Cookie Policy

Sede Legale
Viale Campi Flegrei 55
80124 - Napoli

Sede Operativa
Via G.Porzio 4
Centro Direzionale G1
80143 - Napoli

ISO9001
AI 4394
© Copyright 2022 - Humaninsight Srls - All Rights Reserved
Privacy Policy | Cookie Policy
envelopephone-handsetmap-marker linkedin facebook pinterest youtube rss twitter instagram facebook-blank rss-blank linkedin-blank pinterest youtube twitter instagram